1) To begin, turn the power nozzle over and remove the six (6) screws.

2) Lift off the power nozzle top cover.

3) Remove the light bulb from the housing and subsequently the housing itself.

4) Remove the second inner cover.

5) Trace the wires from the old elbow to the motor and reset circuit breaker.

6) Remove the leads from these two locations.

7) Remove the old elbow and discard.

8) Seat new elbow.

9) Attach new wire leads to the motor and reset circuit breaker.

10) Place new light bulb housing in appropriate location on the inner cover.

11) Screw in light bulb.

12) Replace inner cover.

13) Replace top cover.

14) Replace the six (6) screws.